Building Specs

Building A Square Footage

1,040,000 SF (520' x 2000'), expandable to 1,206,400

Zoning

Industrial

Building Clear Height

40' Clear

Column Bay Spacing

50' x 56' Typical, 60' x 56' Loading Bay

Car Parking

450 Auto Stalls (TBD)

Truck Court

130' Cross Dock Facility

Trailer Storage

285 Off Building Stalls Provided

Walls

Concrete Tilt Wall Panels

Slab Design

7" Thick Strategically Reinforced Concrete Slab, with Sealer

Roof Systems

Fully Adhered 60-mil White TPO

Overhead Doors & Dock Openings

200 Dock Positions and 4 Grade Level Doors

Lighting

High Efficiency LED (Tenant Improvements)

Fire Protection

ESFR Fire Sprinkler System

HVAC

Cambridge Style, Roof Mounted, Gas-fired Unit Heaters

Electrical

4,000 AMP, 277/480 Volt, 3 Phase Service

Building B Square Footage

656,880 SF

Lot Size

141 Acres

Dimensions

510' x 1288'

Building Clear Height

36' Clear

Column Bay Spacing

Two Speed Bays 60' x 56'
and Ten 48'9" x 56' Bays

Exterior Wall Construction

Concrete tilt wall panels, smooth painted finish

Loading Dock Doors

124

Drive-In Doors

4

Car Parking

298

Off Building Trailer Stalls

228

Utilities

Public water, Natural Gas, Electric, Sewer, and Telecom.

Slab Design

7" thick strategically reinforced concrete slab, with Sealer.

Structural Design

Bar joist girders with galvanized steel decking.

Roof Systems

60 Mil Fully Adhered White TPO

Dock Pavement

60' concrete apron - 7" reinforced concrete.

Fire Protection

ESFR Fire Sprinkler System

Plumbing

Water and sanitary line running the length of the building

HVAC

Roof mounted, Cambridge, gas fired unit heaters

Power

4,000 AMP — 277/480 Volt 3 Phase

Interior Lighting

High Efficiency LED

Building C Square Footage

600,000 SF

Lot Size

67.48 Acres

Dimensions

500' x 1200'

Building Clear Height

36' Clear

Column Bay Spacing

Two (2) Speed Bays 60' x 56'
Six (6), 54' x 56' Bays

Exterior Wall Construction

Concrete tilt wall panels, smooth painted finish

Loading Dock Doors

70

Drive-In Doors

4

Car Parking

250

Off Building Trailer Stalls

150

Utilities

Public water, Natural Gas, Electric, Sewer, and Telecom.

Slab Design

7" thick strategically reinforced concrete slab, with Sealer.

Structural Design

Bar joist girders with galvanized steel decking.

Roof Systems

Fully Adhered, 60-mil white-TPO roof membrane (R-30)

Dock Pavement

60' concrete apron - 7" reinforced concrete.

Fire Protection

ESFR Fire Sprinkler System

Plumbing

Interior domestic water loop

HVAC

Roof mounted, Cambridge, gas fired unit heaters

Power

One (1) 4,000 amp, 277/480 volt, 3-phase service.

Interior Lighting

High Efficiency LED